UTM: Configuring SNMP in SonicOS Standard and Enhanced (SW5096)

Return
  • Title

    UTM: Configuring SNMP in SonicOS Standard and Enhanced
  • Resolution

    Article Applies To:

    Gen6 SM E10000 series: NSA E10800, NSA E10400, NSA E10200, NSA E10100
    Gen6 SM 9000 series: NSA 9600, NSA 9400, NSA 9200

    Gen6 NSA Series: NSA 6600, NSA 5600, NSA 4600, NSA 3600, NSA 2600

    Gen5: NSA E8510, E8500, E7500, NSA E6500, NSA E5500, NSA 5000, NSA 4500, NSA 3500, NSA 2400, NSA 2400MX, NSA 220, NSA 220W NSA 240, NSA 250M, NSA250MW
    Gen5 TZ series: TZ 100, TZ 100W, TZ 105, TZ 105W TZ 200, TZ 200W, TZ 205, TZ 205W TZ 210, TZ 210W,TZ 215, TZ 215W.
    Gen4: PRO series: PRO 5060, PRO 4100, PRO 4060,PRO 3060, PRO 2040, PRO 1260
    Gen4: TZ series: TZ 190, TZ 190 W, TZ 180, TZ 180 W, TZ 170, TZ 170 W, TZ 170 SP, TZ 170 SP Wireless, TZ 150, TZ 150 W, TZ 150 Wireless (RevB)

    Firmware/Software Version: All versions.
    Services: SNMP Settings 


    Feature/Application:

    SNMP (Simple Network Management Protocol) is a network protocol used over User Datagram Protocol (UDP) that allows network administrators to monitor the status of the SonicWALL security appliance and receive notification of critical events as they occur on the network. The SonicWALL security appliance supports SNMP v1/v2c and all relevant Management Information Base II (MIB) groups except egp and at. The SonicWALL security appliance replies to SNMP Get commands for MIBII via any interface and supports a custom SonicWALLMIB for generating trap messages. The custom SonicWALL MIB is available for download from the SonicWALL Web site and can be loaded into third-party SNMP management software such as HP Openview, Tivoli, or SNMPC.



    Procedure:

    Section 1: To configure SNMP on SonicOS Standard.
    Section 2:
    To configure SNMP on SonicOS Enhanced.


    To configure SNMP on SonicOS Standard:

     1. Enable SNMP and configure SNMP parameters

    - Login to the SonicWALL Management GUI as admin.
    - Go to System > Administration.
    - Scroll down to the Advanced Management section.
    - Check the box ‘Enable SNMP’.
    - Click on the ‘Configure’ button and supply the parameters for SNMP or keep the defaults for general configuration.
    - Click the ‘OK’ button.
    - Click the Apply button on the top of the page.

     

     For the SNMP functionality, the “Community name” should be the same in the SonicWALL and the SNMP monitoring software.

    2. Creating an access rule to allow SNMP service on the interface.

    - Go to Firewall > Access Rules.
    - Scroll down and click the Add button.
    - Create an access rule as shown below.

    Action: Allow
    Service:
    SNMP
    Source:
    LAN
    Destination: IP Address of the LAN interface.


     


    To configure SNMP on SonicOS Enhanced:

    1. Enable SNMP and configure SNMP parameters

    - Login to the SonicWALL Management GUI as admin.
    - Go to System > Administration.
    - Scroll down to the Advanced Management section.
    - Check the box ‘Enable SNMP’.
    - Click on the ‘Configure’ button and supply the parameters for SNMP or keep the defaults for general configuration.
    - Click the ‘OK’ button.
    - Click the Apply button on the top of the page.


    For the SNMP functionality, the “Community name”  should be the same in the SonicWALL and the SNMP monitoring software.

     2. Enable SNMP on the SonicWALL interface

    - Go to Network > Interfaces and click on the configure button in front of the LAN interface.
    - In the ‘Management’ section, check the ‘SNMP’ box.
    - Click the ‘OK’ button.

    3. Configure the SNMP monitoring software.

    - Open the SNMP software and register the SonicWALL. (You can download and install a free edition of PRTG from http://www.paessler.com/prtg/download)

    Screen shots for PRTG (V8.1.2.1775) are attached below, just enter the SonicWALL appliance's LAN IP address, along with the community string and it will start gathering data from the SonicWALL

    Conclusion:

    By performing the above steps, you should be able to configure SNMP monitoring on the SonicWALL device.

     

  • Key Words

    5096


Product(s):
SonicWALL NSA Series
4500, 3500, 250MW, 250M, 2400
SonicWALL E-Class NSA Series
E8510, E8500, E7500, E6500, E5500
SonicWALL TZ Series
215W, 215, 210W, 210, 205, 200W, 200, 105, 100W, 100
SonicWALL PRO Series
5060, 4100, 4060, 3060, 2040, 1260
TZ Series
190W, 190, 180W, 180, 170, 150W, 150

Topic(s):
Technical Solutions

Article History:
Created on: 6/28/2008
Last Update on: 5/13/2014

Feedback submitted.

Did this article help?

[Select Rating]

Thank you for your rating!

Close